SERVER_MODE in GET_UC_SETTING returns wrong value for JWP

book

Article ID: 84889

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
N/A

The Script Function GET_UC_SETTING with Setting / Parameter SERVER_MODE returns a wrong return code for a JWP.

:SET &RET# = GET_UC_SETTING(SERVER_MODE, "SO12#WP009"):P Server Mode UC4#WP009 is --&RET#--

Investigation
Activation report:

2017-10-30 13:10:16 - U00020408 Server Mode UC4#WP009 is -- --

WP009 is an active JWP.

Results
Actual:  Returns a blank.
Expected:  
SERVER_MODE returns "J" for JWP.

Cause

Cause type:
Defect
Root Cause: GET_UC_SETTING with opcode SERVER_MODE does not work for JWP.

Environment

Release: AUTWAB99000-12.0-Automic Workload Automation-Base Edition
Component:

Resolution

Update to a fix version listed below or a newer version if available.



Fix Status: In Progress

Fix Version(s):
Component(s): AE Server and Initialdata

Automation Engine 12.2.0 - Planned release date: 2018-06-29
Automation Engine 12.1.1 - Available
Automation Engine 12.0.4 - Available
Automation Engine 11.2.7 - Available

Additional Information

Workaround :
N/A