Setting Post Condition to restart task, with entries in Variables and Prompts field of the task, task remains in Generating status
search cancel

Setting Post Condition to restart task, with entries in Variables and Prompts field of the task, task remains in Generating status

book

Article ID: 84843

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
U00003590 UCUDB - DB error: 'SQLBindParameter', 'ERROR ', 'HY104', 'Invalid precision value'

When setting a Post Condition to restart a task that has entries in the Variables and Prompts field of the task the task will remain in a status of Generating and the above error message will be displayed.

This occurs on Automation Engine systems running with a SQL Server database.

Environment

OS Version: N/A

Cause

Cause type:
Defect
Root Cause: Jobs will get stuck in a Generating status and throw a 'SQLBindParameter' error. Tthe SQL Server ODBC driver does not support bind parameters with null values and the jobs will get stuck in a Generating status.

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Automation Engine 12.1.1 - Available
Automation Engine 12.0.4 - Available
Automation Engine 11.2.6 - Available

Additional Information

Workaround :
Remove the Variables and Prompts field value.