CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message : N/A
When exporting folders with links and objects, the objects and links may be imported into a different folder.
Imported object structure is not the same as the exported structure.
Investigation I.E.: Crosslinked objects in 2 folders Export: -Folder: Script 1, Link to Script 2 -Subfolder: Script 2, Link to Script 1 Import: -Folder: Script 1, Script 2 -Subfolder: Link to Script 1, Link to Script 2
Cause
Cause type: Defect Root Cause: The interpretation of object xml export with folders was not correct in some versions of the AE.
Environment
OS Version: N/A
Resolution
Update to a fix version listed below or a newer version if available.
Fix Status: In Progress
Fix Version(s): Automation.Engine 12.2.0 - Planned release date - 2018-06-29 Automation.Engine 12.1.1 - Available Automation.Engine 12.0.4 - Available Automation.Engine 11.2.7 - Available
Additional Information
Workaround : Export / Import Objects / Folders with the Transport Case