Before upgrading to Endevor V18, there was an option to use foreground - "4 ENVIRONMENT" and then "7 TYPE SEQUENCE" to update the Type Sequence
This is no longer available in v18 - ibut now it is display only.
How do I update the Type Sequencing in Endevor v18?
New to Endevor v18, you can no longer update the Type Sequence member in foreground. Starting with Endevor v18, you need to update the Global Type Sequence member in the PARMLIB.
Use the following steps to find the Type Sequence member:
1) Go to "4 ENVIRONMENT" and then "1 SITE" and on the second page look for the section titled:
---------- Parameter Library Information -----
This contains the PARMLIB data set name and the Type Sequence member name:
Parmlib Data Set....
Type Sequence Mbr....
2) Edit the Type Sequence member in the PARMLIB library.
3) No additional processing or assemblies are needed. Log out of Endevor and log back on to get the new Type Sequence.
See KB Article Id: 37635 if you want to set up a different Type Sequences order for different Systems.