U0011608 The internal table of active hosts is full.
book
Article ID: 84810
calendar_today
Updated On:
Products
CA Automic Workload Automation - Automation Engine
Issue/Introduction
Error Message :
U0011608 The internal table of active hosts is full
When starting an agent > the following issue occurs and the agent got disconnected:
U0011608 The internal table of active hosts is full.
Environment
Release: AUTWAB99000-10.0-Automic Workload Automation-Base Edition
Component:
Cause
Cause type:
By design
Root Cause: There is a limitation in the code when more than 15.360 agents are connected to the AE
Resolution
Update to a fix version listed below or a newer version if available.
This was enhanced to a maximum number of Agents to 30.000 in 10.0.8 HF1
Fix Status: Released
Fix Version(s):
Automation Engine in version:
10.0.8 HF1 has been released on 2016-08-09
Additional Information
Workaround :
N/A