Upon startup of the node, the engine Launcher started before DQM so several scheduled Jobs Aborted right Away with the "Could not Submit" error as DQM was not present.
Error Messages in universe.log: |ERROR|X|IO |pid=p.t| u_io_launch_engines | Unable to check DQM start before starting LAN in area X ... |ERROR|X|IO |pid=p.t| owls_connect_auth | k_connect_auth_timeout(nodename/DQM) returns error [200] |ERROR|X|IO |pid=p.t| o_callsrv_connect_r | Connection error 111 [Errno syserror 111: Connection refused]
Environment
OS: All
Cause
Cause type: Defect Root Cause: Timing issue, DQM should start before Launcher
Resolution
Workaround : Relaunching the Aborted Jobs or Disabling the automatic startup of the Launcher.
Solution: update to a fix version listed below or a newer version if available.
Fix Status: Released
Fix Version(s): Component: Application.Server Dollar Universe 6.9.01 - Available