Agents in System Overview show negative resources for any value over 32767

book

Article ID: 84721

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine

Issue/Introduction

Error Message :
N/A

Agents in the System Overview show negative resources for any value over 32,767.

This only occurs when using the Java User Interface (UI).  This does not occur when using the Automic Web Interface.


Investigation

Open the Agent Properties and set the resources.

When setting the resources value to 32767 or under, it shows correctly in the UI and in database:

<Please see attached file for image>

dg5q28m2fmw2.png

Setting the value over 32767, it shows a negative value:

<Please see attached file for image>

urg8ycvf67jc.png

However, the value in database is correct and the agent still functions as expected:

<Please see attached file for image>

2vlfusgoj8cm.png

Cause

Cause type:
Defect
Root Cause: Invalid display when using the Java UI.

Environment

OS Version: N/A

Resolution

N/A

Fix Status: No Fix

Additional Information

Workaround :
  1. Use the ECC/AWI
or
  1. Set the variable with UC_HOSTCHAR_DEFAULT

Attachments

1558692916397000084721_sktwi1f5rjvs16lw2.png get_app
1558692914588000084721_sktwi1f5rjvs16lw1.png get_app
1558692912778000084721_sktwi1f5rjvs16lw0.png get_app