EXEC VARA used in PromptSets not resolved correctly upon execution

book

Article ID: 84595

calendar_today

Updated On:

Products

CA Automic Workload Automation - Automation Engine AUTOMIC WORKLOAD AUTOMATION

Issue/Introduction

Error Message :
N/A

When referencing several EXEC VARA variables with curly brackets in a PromptSet , they will not be resolved correctly upon execution of the calling task.

They will be resolved bottom up and the script called by the EXEC VARA reference in the bottom will be used in all other fields, except for the top one.

 

Cause

Cause type:
Defect
Root Cause: Variables of type EXECUTION are not resolved correctly if several different variables are used in the same prompt, or as default values in a prompt.

Environment

OS Version: N/A

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Component(s) : AE Server and Initial Data

Automation Engine 12.1.1 - Available
Automation Engine 12.0.4 - Available
Automation Engine 11.2.6 - Available

Additional Information

Workaround :
N/A