Error Message :
When increasing the main log level to 0,SECURITY we find this kind of messages in universe.log
|WARN |X|IO |pid=pid.tid| o_io_cache_data_provider_ | Group not found locally: 600
|ERROR|X|IO |pid=pid.tid| o_io_cache_get | Object not found

Newly created Dollar Universe 6 nodes added to an existing "Node View" are not automatically synchronized with the corresponding  "Security Groups". 

As a result, command line executions like uxordre / uxadd will not work by default since the systems user will belong to the "Read-only" group.

UVC Users will probably also be affected as they won't be able to Launch nor Update Jobs.


 

Environment

OS: All
OS Version: All

Cause

Cause type:
Defect
Root Cause: Security Groups are not synchronized automatically on the nodes recently added to a Node View

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Component(s): Univiewer Management Server

Dollar Universe 6.8.41 - Available

Additional Information

Workaround :
Manually launch a Full Synchronization on the node from UVC (or delete u_sync.dta file from the folder data).