Access denied or Permissions issues on DUAS Nodes recently added to Node View
book
Article ID: 84518
calendar_today
Updated On:
Products
CA Automic Dollar Universe
Issue/Introduction
Error Message : When increasing the main log level to 0,SECURITY we find this kind of messages in universe.log |WARN |X|IO |pid=pid.tid| o_io_cache_data_provider_ | Group not found locally: 600 |ERROR|X|IO |pid=pid.tid| o_io_cache_get | Object not found
Newly created Dollar Universe 6 nodes added to an existing "Node View" are not automatically synchronized with the corresponding "Security Groups".
As a result, command line executions like uxordre / uxadd will not work by default since the systems user will belong to the "Read-only" group.
UVC Users will probably also be affected as they won't be able to Launch nor Update Jobs.
Environment
OS: All OS Version: All
Cause
Cause type: Defect Root Cause: Security Groups are not synchronized automatically on the nodes recently added to a Node View
Resolution
Update to a fix version listed below or a newer version if available.
Fix Status: Released
Fix Version(s): Component(s): Univiewer Management Server
Dollar Universe 6.8.41 - Available
Additional Information
Workaround : Manually launch a Full Synchronization on the node from UVC (or delete u_sync.dta file from the folder data).