The message "o_init_trn_security error -1" appears in universe.log

book

Article ID: 84415

calendar_today

Updated On:

Products

CA Automic Dollar Universe

Issue/Introduction

Error Message :
In universe.log:
|ERROR|X|CDJ|pid=12124194.520| owls_process_request | o_init_trn_security error -1.

Since Dollar Universe 6.8.01, the above error appears in universe.log every two minutes.
In the UVMS, the Optional Service Consolidation of Job Summary , is enabled.

Cause

Cause type:
Defect
Root Cause: Enabling Consolidation of Job Summary on UVMS could generate error messages on DUAS nodes.

Environment

OS: IBM AIX
OS Version: The issue was observed on AIX, but could happen on other OS like HP-UX, but does not appear in Linux / Windows

Resolution

Update to a fix version listed below or a newer version if available.

Fix Status: Released

Fix Version(s):
Dollar Universe 6.8.41 - released 15th January 2018

Additional Information

Workaround :
Disabling the Optional Service "Consolidation of Job Summary" on UVMS