Object Name incorrect in Deadlock/Timeout screen within Sysview for Db2
search cancel

Object Name incorrect in Deadlock/Timeout screen within Sysview for Db2

book

Article ID: 8397

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS

Issue/Introduction

When using the Sysview Performance Management Option for Db2 for z/OS (IDB2) Online Deadlock/Timeout screen, why does it sometimes show
the name of the object and sometimes shows the DBID.OBID of that object.

Here is an example the report shows 00000277.00002334 for the object that last week was showing its object name:
xxxxxxxxx.yyyyyyyy

Resolution

It is possible that the OBIDTBL data set contains outdated information. Search for the objects by name in this data set and see
if their associated DBID/OBID information is correct. If it is not, you can simply run the IDB2 IDOBLOAD utility to reload this data set.