The SPM Test for URL monitoring fails with the following error on the Spectrum OneClick Console:
SPC-OCC-10183: The following errors(s) occurred when attempting to run the selected test(s):
SPC-OCC-1641: Failure.
The URL monitoring test fails with status 'Bad Configuration' because the read community string is being configured at the SystemEDGE Agent side.
The read-write community string must be configured for the URL monitoring to work properly.
Please edit the sysedge.cf file under the port161/1691 directory on the agent and configure it to read-write community string, then on the Spectrum OneClick Console change the community string to read-write for the agent. Please poll the device again for the changes to take effect.
For additional information, please refer to the Service Response Monitor User Guide:
https://support.ca.com/cadocs/0/CA%20Virtual%20Assurance%20for%20Infrastructure%20Managers%2012%208-ENU/Bookshelf_Files/PDF/VA_SRMUser_ENU.pdf