When performing a CA Endevor RESTORE of all Production elements, the job abends with a SE37 after 323 elements were restored.
search cancel

When performing a CA Endevor RESTORE of all Production elements, the job abends with a SE37 after 323 elements were restored.

book

Article ID: 8034

calendar_today

Updated On:

Products

Endevor Endevor Natural Integration Endevor - ECLIPSE Plugin Endevor - Enterprise Workbench

Issue/Introduction

When performing a CA Endevor RESTORE of all Production elements:

RESTORE ELEMENT A* THRU Z* 
FROM FILE ARCHIVE
ENV 'PROD' SYS * SUBSYSTEM *

 

the job abends with a SE37 after 323 elements were restored -

C1G0140S  ENDEVOR - BC1PSMGR ABENDED CODE=SE37

Environment

z/OS

Cause

IEC032I E37-08,IFG0554P,SIQA28R,NDVRBAT,SYS00018,40AB,WRT001,04034379,   SYS17241.T132834.RA000.SIQA28R.R0C36456 

 

E37 

 

Explanation: The error occurred when an output operation was requested. The data set was on a direct access or magnetic tape device. This system completion code is accompanied by message IEC032I. Refer to the explanation of message IEC032I for complete information about the task that was ended and for an explanation of the return code (rc in the message text) in register 15. 

 

08 

A multi-volume physical sequential data set was being written on a direct access device. All space was filled on the volume, and an attempt was made to obtain space on the next specified volume. Either the space was not available on that volume, the data set already existed on that volume, or there is no space available in the VTOC or the VTOC index. The message contains the volume serial number of the last volume used.

Resolution

Find a Storage Class that has more free space and volumes available.