Issue/Introduction

Steps to Reproduce: 

1. Navigate to > Administration 

2. Click on > Lookups 

3. Search for ‘Investment Type’ (ID= INV_TYPE / Static Dependent List)

4. Click on ‘Values’ tab 

5. Expand Project Investment 

6. Expand ‘Six Sigma’ 

7. Deactivate ‘Define’ 

8. Navigate to ‘Project’ 

9. Click on [Build Power Filter] 

10. Object= Select ‘Stage’ 35

11. Right = click on binocular icon > Tick ‘Six Sigma’ and Click on Add 

12. Select Evaluate 

Expected Result: Successful Evaluated Expression 

Actual Result: Invalid expression 

Cause

This issue is documented as defect DE35255 

Environment

14.X, 15.1 and 15.2

Resolution

This is resolved in 15.3

 

 

Additional Information

Workaround:

When the power filter is created, manually update the expression to remove the inactive value and expression validation will be saved successfully. 