nimalarm options updated

book

Article ID: 7861

calendar_today

Updated On:

Products

DX Infrastructure Management NIMSOFT PROBES

Issue/Introduction

Alarms generated with the nimalarm utility 8.4 are not displayed neither in the alarm window (IM) nor in the USM or in Doctor Nimbus.

Cause

This occurs to customers who configured nimalarm in v8.0 or 8.2 when the option -V was 'message values':

 

<Please see attached file for image>

nimalarm_8.2.png

Because from 8.4 -v is 'message values' and -V became ‘print version’:

 

 

<Please see attached file for image>

nimalarm_8.4.png

Environment

CA UIM 8.4 and superior upgraded from 8.0 or 8.2.

Resolution

The new nimalarm needs to be reconfigured according to its updated options.

Additional Information

Please check the guide for further information on the nimalarm utility:

The NimAlarm Utility

Attachments

1558700204663000007861_sktwi1f5rjvs16oyz.png get_app
1558700202779000007861_sktwi1f5rjvs16oyy.png get_app