CA Panvalet online interface running on Fujitsu MSP gets a B78 error when the LMP Key is about to expire. Batch works fine.
search cancel

CA Panvalet online interface running on Fujitsu MSP gets a B78 error when the LMP Key is about to expire. Batch works fine.

book

Article ID: 7741

calendar_today

Updated On:

Products

Panvalet

Issue/Introduction

CA Panvalet online interface running on Fujitsu MSP will get a B78 error when the LMP Keys are about to expire. 

CAS9013A    PRODUCT X7 ABOUT TO EXPIRE OR IS EXPIRED AND IS IN USE
CAS9013A    PRODUCT X8 ABOUT TO EXPIRE OR IS EXPIRED AND IS IN USE

 

SAA100RE SA100AA -  COMPLETION CODE - SYSTEM=B78 USER=0000

 

Users see:

+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + 
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
+ +                PFD PROCESSOR ABENDED                + +
+ +                TASK ABEND CODE B78                  + +
+ +                                                     + +
+ +                                                     + +
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + +
+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + +

Environment

Fujitsu MSP

Cause

It appears that when the CAS9013A warning messages are issued on a Fujitsu MSP system, it causes the CA Panvalet ISPF interface to fail with the B78 error.  This does not occur with the IBM operating system. 

Resolution

The Emergency Key Generator (EKG) used for after hour situations does not resolve the problem. 

Need new permanent X7 and X8 LMP keys or if new permanent LMP keys can't be provided until the next business day, need temporary LMP keys from a Customer Care Representative with an expire date 60 days out to eliminate the CAS9 warning messages. 

Once the CAS9 messages are eliminated, the B78 is eliminated and the Panvalet online system works.