Devices discovered by a VMWare probe attached to a secondary HUB are not appearing on the UMP.
There are no errors in the probe logs.
Dr Nimbus does not see any probe_discovery messages from the probe on the primary HUB.
Cause
Devices discovered by the vmware probe will only be displayed when the probe_discovery messages from the probe are received by the discovery server running on the primary hub.
As the probe_discovery messages are not received, the discovery server cannot add the devices into the database.
The probe_discovery messages are not reaching the primary hub because no queue has been setup to transfer the messages from the secondary hub to the primary hub
Environment
Release: CNMSPP99000-8.47-Unified Infrastructure Mgmt-Server Pack-- On Prem Component:
Resolution
Follow the instructions here to create the required queues to allow the discovery messages to flow from the secondary hub to the primary hub.