CDM probe not starting on some servers, throws start after probe not enabled error
search cancel

CDM probe not starting on some servers, throws start after probe not enabled error

book

Article ID: 7555

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM) Unified Infrastructure Management for Mainframe CA Unified Infrastructure Management SaaS (Nimsoft / UIM)

Issue/Introduction

The cdm probe is not starting and has a "Max Restarts" error in the cdm log file.

The cdm probe use to work on these servers.

If you set the controller to loglevel 5 and restart the robot you will see the following line

Controller: Can not start cdm, start after probe not enabled (cluster)

Environment

- UIM 8.x or later

Cause

- If the cluster probe is installed on the same machine as cdm, the cluster probe MUST BE ACTIVATED first.

Resolution

 - Deactivate cdm probe

 - Activate the cluster probe

 - Activate the cdm probe

NOTE: If you no longer need the cluster probe, uninstall it through the Infrastructure Manager or Admin Console GUI.