USM Group Automation not working - can not find nis_server
search cancel

USM Group Automation not working - can not find nis_server

book

Article ID: 7517

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

When trying to use Application Discovery were are receiving the following stacktrace.

 

An unknown error has occurred.
Refreshing your browser may resolve the issue.

Details:
com.firehunter.ump.exceptions.DataFactoryException : Received status (4) on response (for sendRcv) for cmd = 'nametoip' name = 'nis_server'
Please check the log for more information.

Environment

Release: CNMSPP99000-8.51-Unified Infrastructure Mgmt-Server Pack-- On Prem
Component:

Cause

This was due to the wasp <ump_common> missing the address to nis_server.

Resolution

  1. Edit the UMP's wasp.cfg file either via Raw Configure or directly on the system itself.
  2. Add the following key value pair under <ump_common>
  3. nis_server = DOMAIN/HUB/ROBOT/nis_server
  4. Change the DOMAIN/HUB/ROBOT address to point to your primary hub, which is where nis_server should be installed. Please note, the address is case_sensitive
  5. Save the file, and restart the UMP Wasp. The issue should now be resolved.