GenGen - Workstation ToolsetGen - Host EncyclopediaGen - Run Time Distributed
Issue/Introduction
RUN PROGRAM(&PROGRAM.X) &DB2PRMS &DB2PLAN &DB2LLIB RUN PROGRAM(TICINSTX) PARMS('STACK(512K) /E E') PLAN(AMDTINST) CN7P1000 Generating installation control. CN7P1000 Installation control generated. SET RC = &LASTCC /*LKA88076*/ SET RC = 12 /*LKA88076*/ CONTROL NOLIST NOCONLIST NOSYMLIST CONTROL NOLIST NOCONLIST NOSYMLIST SET RC = &LASTCC SET RC = 12
Environment
z/OS, DB2, COBOL, IMS
Cause
Customer built the encyclopedia by copying software libraries from a working encyclopedia and running the bind CE jobs. The COBOL 5 PTFs had been applied.
Resolution
Missing TIRC2VER variable in PARMLIB(TIRHE). Found by reviewing <uid>.IEF.TISYSPRT dataset.