After installing and configuring ADA Standard monitor, ADA Collector service fails to start and below errors are present in SACollector logs:
********** SACollector **********
05:16:58 Severity 1 - SACollector starting up
05:16:58 Severity 2 - Precision timer frequency is 1,842,209,835,976 ticks per second
05:16:58 Severity 2 - hr_test failure 0x87ff0008 Invalid network interface card specified at saPacketCapture.cpp 3254 -
05:16:58 Severity 2 - hr_test failure 0x87ff0008 Invalid network interface card specified at saPacketCapture.cpp 3111 -
05:16:58 Severity 2 - hr_test failure 0x87ff0008 Invalid network interface card specified at SASpanReceiver.cpp 408 -
05:16:58 Severity 2 - hr_test failure 0x87ff0008 Invalid network interface card specified at SASpanReceiver.cpp 104 -
05:16:58 Severity 2 - hr_test failure 0x87ff0008 Invalid network interface card specified at SACollector.cpp 648 - Error initializing collector input thread 'xxx.xxx.xxx.xxx Packets'
05:16:58 Severity 2 - Abnormal exit from CreateCollectorInputThread() hr=-2013331448
05:16:58 Severity 2 - hr_test failure 0x87ff0008 Invalid network interface card specified at SACollector.cpp 2017 -
05:16:58 Severity 3 - NQMultipleSignalSynHandle2() return code hrInputFeedError=-2013331448
05:16:58 Severity 2 - ServiceShutdownNotification before FlushAllInputThreads()
05:16:58 Severity 3 - WaitForAllInputThreadCompletion() return code hrInputFeedError=-2013331448
05:16:58 Severity 2 - hr_test failure 0x87ff0008 Invalid network interface card specified at SACollector.cpp 542 -
05:16:58 Severity 2 - SACollectorProgramEntry => wrapup: hr=-2013331448
05:16:58 Severity 1 - Shutting Down
ADA 11.0Window 2012 R2
This problem can be occurred due to invalid NIC and IP Address configuration on ADA Standard Monitor
Follow the below guidelines while configuring Network interface cards on ADA Monitor machine.