Solve Access 5.0 - S0F8 starting Netmaster after migrating to z/OS 2.3
search cancel

Solve Access 5.0 - S0F8 starting Netmaster after migrating to z/OS 2.3

book

Article ID: 72586

calendar_today

Updated On:

Products

CMDB for z/OS NetSpy Network Performance NetMaster Network Automation SOLVE NetMaster Network Management for SNA NetMaster Network Management for TCP/IP NetMaster File Transfer Management SOLVE:Operations Automation SOLVE:Access Session Management SOLVE:FTS

Issue/Introduction

We migrated our TEST lpar to z/OS 2.3 today. Starting Netmaster we get a S0F8 abend.
Seems to have problems with parm XM='ZIIP' After changing to XM='TASK' Netmaster was starting correctly. 

*N01101 SOLVE ABEND S-0F8 ID=AAAAAA  JN=NMT DT=2018064 TM=15223497 
*N01102 SRC=AB PRD=SOLVE INTLVL=060700 SP=1007 ABC=S-0F8 
*N01103 
IEA794I SVC DUMP HAS CAPTURED: 894 
894 DUMPID=001 REQUESTED BY JOB (NMT ) 
894 DUMP TITLE=N01101 SOLVE ABEND S-0F8 ID=AAAAAAA JN=NMT DT=2018064 
894 TM=15223497 
BPXP018I THREAD 1789C80000000000, IN PROCESS 34013251, ENDED 906 
906 WITHOUT BEING UNDUBBED WITH COMPLETION CODE 840F8000 
906 , AND REASON CODE 00000004. 
IEF450I NMT NMT - ABEND=S0F8 U0000 REASON=00000004 908 
908 TIME=15.22.36 
 

Environment

Release: SLOPFC00200-12.1-NetMaster-File Transfer Management
Component:

Resolution

IBM APAR OA54317 resolve the S-OF8 abend.

The link to the APAR is
http://www-01.ibm.com/support/docview.wss?uid=isg1OA54317  
 

APAR status

  • Closed as program error.

Error description



  • SMSVSAM ABEND0F8 RC4 in IDA019C2 at offset x'2F0' at RMID
    UA92399 when called in SRB mode.

    Additional Keywords:
    SMSVSAM RLS VSAMRLS DF122
    RLSPSP/K


Local fix

  • If using NETMASTER run with XM=TASK in the RUNSYSIN parameter.
    Making this change may move task processing back to a regular
    CP, which may impact customer MIPS usage.

Problem summary



  • ***************************************************************
    * USERS AFFECTED: *
    * All VSAM RLS users who run tasks in SRB mode *
    ****************************************************************
    * PROBLEM DESCRIPTION: *
    * While in SRB mode, if a SHOWCB command is issued, an *
    * ABEND0F8 RC4 will occur out of IDA019C2 as a result of a *
    * GETMAIN failing. *
    ****************************************************************
    * RECOMMENDATION: *
    * Apply PTF *
    ****************************************************************
    When a user issued a SHOWCB against a data set open for RLS,
    IDA019C1 tried to issue a PC, calling IDA019C2 to establish an
    ESTAE and call RLS. Doing this requires a GETMAIN and FREEMAIN
    to be called for the ESTAE parameters which cannot be done under
    an SRB. Therefore, when IDA019C1 tried to issue a PC while in
    SRB mode, the GETMAIN in IDA019C2 failed and returned an
    ABEND0F8 RC4.


Problem conclusion

  • Code was changed such that an ESTAE will not be set up and a
    GETMAIN/FREEMAIN will not be called if IDA019C2 is called while
    in SRB mode.

Temporary fix

 

Comments

APAR Information

  • APAR number     OA54317

  • Reported component name

    VSAM REC LEV SH

  • Reported component ID

    5695DF122

  • Reported release

    220

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-11-01

  • Closed date

    2018-02-14

  • Last modified date

    2018-02-14

  • APAR is sysrouted FROM one or more of the following:



  • APAR is sysrouted TO one or more of the following:



    UA95316



Modules/Macros





  • IDA019C2


     



Fix information




  • Fixed component name



    VSAM REC LEV SH


  • Fixed component ID



    5695DF122



Applicable component levels





 

Additional Information

This IBM fix does not completely correct the problem.
It will result in a S0C3 abend. Please see KB000091959 for additional  Netmaster and IBM fixes to fully correct the problem.