Unexpected OQ098002 or OQ093031 in OLQ
search cancel

Unexpected OQ098002 or OQ093031 in OLQ

book

Article ID: 72285

calendar_today

Updated On:

Products

IDMS IDMS - Database IDMS - ADS

Issue/Introduction

If all (true for both command mode and menu mode) or part (true only for menu mode) of a record's CALC key is defined as USAGE COMP and is more than one fullword in length internally (i.e. PIC 9(n) where n>=10), then unexpected results can occur in OLQ.

The nature of the unexpected results includes, but is not limited to, the following:-
OLQ 098002 No Record Found (when the record exists), or
OLQ 093031 Key field data type does not match constant.

Environment

CA IDMS, all supported releases.

Resolution

OLQ does not support doubleword fields as key fields (calc or index).
The recommendation is to use the CA-IDMS SQL Option to access such data.

Additional Information

CA Online Query for CA IDMS - (User Guide)
Accessing Network-Defined Databases - (from the SQL Reference Guide)