After manually clearing an alarm generated from a Spectrum Watch, the watch fails to generate a new alarm if the threshold is exceeded again.
DX NetOps Spectrum all releases
Watches that are manually cleared will not be re-evaluated by default.
Spectrum Watches need to be configured to re-evaluate the watch when the watch is manually cleared.
For watches configured to "Generate Alarm", you will need to check the box labeled "Reset watch upon user clearing alarm":
For watches configured to "Generate Event(s)", you will need to add the 0x10706 event to the "when deactivated/all instances reset" field. The 0x10706 event is the event generated by Spectrum when a user manually clears an alarm.
Please reference the "Watches" section of the documentation for more details on creating and editing Spectrum watches:
Working With Watches