After upgrading to 10.2, the SiteMinder Single Sign-on host registration fails.

book

Article ID: 6997

calendar_today

Updated On:

Products

CA Spectrum

Issue/Introduction

When registering the Spectrum OneClick server as a trusted host on the OneClick Single Sign-On SiteMinder configuration page it fails with the following error message:

SPC-OCA-10300: Unable to register host with Policy Server. Verify parameters.

Cause

The incorrect version of the smregHost executable and the SiteMinder libraries were shipped with 10.2

 

Environment

Spectrum 10.2CA SiteMinder 12.52 SP01, 12.6

Resolution

This issues is resolved with Spectrum_10.02.00.PTF_10.02.022 for Spectrum version 10.2.

Spectrum will now ship the correct version of the smregHost executable and the SiteMinder libraries to integrate successfully with SiteMinder.