S30A abend occurs after MANT task terminates with U2700 in CA 11
search cancel

S30A abend occurs after MANT task terminates with U2700 in CA 11

book

Article ID: 69697

calendar_today

Updated On:

Products

Workload Automation Restart Option for z/OS Schedulers (CA 11)

Issue/Introduction

S30A abend may occur after MANT task terminates with U2700

 

Cause

The S30A is from a FREEMAIN generated by a FREEPOOL macro.  This FREEPOOL is executed for a file never opened (because the dynamic allocation failed).  The programmer checked for the file being open and bypassed the CLOSE but not the FREEPOOL.

Resolution

The MANT task should bypass executing the FREEPOOL macro if the Purge and Report files are not open.  This is corrected by PTF RO36794.