When running the CA Mainframe Application Tuner 11.0 IVP we are getting an "IEW2456E 9207 SYMBOL IGZCBSO UNRESOLVED" error.
book
Article ID: 6965
calendar_today
Updated On:
Products
Mainframe Application Tuner
Issue/Introduction
When running the CA Mainframe Application Tuner 11.0 IVP we are getting an "IEW2456E 9207 SYMBOL IGZCBSO UNRESOLVED" error.
Environment
Release:
Component: MATUNE
Resolution
Include **.SCEELKED data set in the SYSLIB concatenation of the LKED step in the link-edit job.