Spectrum OneClick log showing the following error processing event id 0x3e40136:
May 23, 2017 15:20:14.471 - Error parsing event type 0x3e40136 : 9u
May 23, 2017 15:20:14.472 - Please check the event format file for any errors
Error in the associated $SPECROOT/SG-Support/CsEvFormat/Event03e40136_en_US file highlighted below:
{d "%w- %d %m-, %Y - %T"} - A "trapRX200Plus12CurrentAlarm" event has occurred, from {t} device, named {m}.
- RX200 Modules positive 12 volt current parameter goes out of range.
trapIdentifier = {I 1}
trapNetworkElemModelNumber = {S 2}
trapNetworkElemSerialNum = {S 3}
trapPerceivedSeverity = {T trapPerceivedSeverity 4}
trapNetworkElemOperState = {T trapNetworkElemOperState 5}
trapNetworkElemAlarmStatus = {T trapNetworkElemAlarmStatus 6}
trapNetworkElemAdminState = {T trapNetworkElemAdminState 7}
trapNetworkElemAvailStatus = {T trapNetworkElemAvailStatus 8}
trapText = {S 9u} \000atrapChangedObjectID = {o 10}
trapChangedObjectId = {o 10}
trapChangedValueInteger = {I 11}
trapNETrapLastTrapTimeStamp = {G 12}
(event [{e}])
RESOLUTION: This issue is scheduled to be addressed in Spectrum 10.03.00.00.
WORK_AROUND: Modify the $SPECROOT/SG-Support/CsEvFormat/Event03e40136_en_US file so it looks like the following highlighted below:
{d "%w- %d %m-, %Y - %T"} - A "trapRX200Plus12CurrentAlarm" event has occurred, from {t} device, named {m}. - RX200 Modules positive 12 volt current parameter goes out of range. trapIdentifier = {I 1} trapNetworkElemModelNumber = {S 2} trapNetworkElemSerialNum = {S 3} trapPerceivedSeverity = {T trapPerceivedSeverity 4} trapNetworkElemOperState = {T trapNetworkElemOperState 5} trapNetworkElemAlarmStatus = {T trapNetworkElemAlarmStatus 6} trapNetworkElemAdminState = {T trapNetworkElemAdminState 7} trapNetworkElemAvailStatus = {T trapNetworkElemAvailStatus 8} trapText = {S 9} trapChangedObjectId = {o 10} trapChangedValueInteger = {I 11} trapNETrapLastTrapTimeStamp = {G 12} (event [{e}])