When adding Windows Host as a monitoring target in snmpcollector probe, device Type of Windows Host is classified as 'Switch'

book

Article ID: 6896

calendar_today

Updated On:

Products

DX Infrastructure Management NIMSOFT PROBES

Issue/Introduction

Device Services property for Windows Domain Controller is classified as “SWITCH” rather than “HOST”, in snmpcollector probe.

USM also display the type of the device as "Switch".

 

<Please see attached file for image>

Windows_Domain_Controller.png

 

Cause

This is a defect.

The defect have been fixed with DCD (device certification deployer) package 1.5

Environment

snmpcollector 3.31Target device is Windows Domain Controller (SNMP service enabled)

Resolution

1. Deactivate snmpcollector probe.
2. Add a row (yellow highlighted) into <snmpcollector>\DeviceSupport\DeviceTypes.xml
Take a backup before editing.

  <Servers>
    <sysObjectID>1.3.6.1.4.1.2.3.1.2.1.1.3</sysObjectID>
    <sysObjectID>1.3.6.1.4.1.9.1.746</sysObjectID>
    <sysObjectID>1.3.6.1.4.1.99.1.1.3.11</sysObjectID>
    <sysObjectID>1.3.6.1.4.1.311.1.1.3.1.1</sysObjectID>
    <sysObjectID>1.3.6.1.4.1.311.1.1.3.1.2</sysObjectID>
    <sysObjectID>1.3.6.1.4.1.311.1.1.3.1.3</sysObjectID>
 
3. Activate snmpcollector probe.
4. Run "Force Component Rediscovery" for Domain Controller Server profile.
    4-1. Go to snmpcollector > Profiles > Highlight profile name.
    4-2. Click options menu > Force Component Rediscovery

Attachments