How to check whether a load module includes the CA Optimizer/II tools in a specific LOAD library?.
How can this be checked working with the Optimizer/II utilities?.
Optimizer/II 8.5
The load module information can be checked by running the Management Reporting System (MRS) utility and check the CA-OPT value.
If the value is the "NONE", the load module does not include the Optimizer/II tools. But, if the value is the "OPT/II", then the load module includes the Optimizer/II tools.
Sample JCL:
//********************************************************************
//** MANAGEMENT REPORTING SYSTEM PROCEDURE **
//********************************************************************
//CAIMRSII PROC OPTLIB='Public.Optimize2.CAILIB', * LOAD LIB
// LPALIB='Public.Optimize2.CAILPA', * LPA LIB
// LIBRARY='Public.User.LOADLIB', * USER LIBRARY
// SYSOUT='*' * SYSOUT CLASS
//MRS EXEC PGM=CAOUMRS,REGION=256K
//STEPLIB DD DISP=SHR,DSN=&OPTLIB
// DD DISP=SHR,DSN=&LPALIB
//SYSLIB DD DISP=SHR,DSN=&LIBRARY
//SYSPRINT DD SYSOUT=&SYSOUT
// PEND
//STEP01 EXEC CAIMRSII
Sample report:
MODULE MODULE-SIZE CSECT CSECT-SIZE PROC-SIZE DATA-SIZE COMPILER-ID REL DATE TIME CA-OPT REL DCXPSRBFWIELHO
TEST001 32,560 TEST001 17,328 9,780 7,548 VSR1 5740-CB1 2.4 12/20/2000 21.36.39 OPT/II 7.0 .........IE.H.
TEST002 55,600 TEST002 24,048 8,186 15,862 VSR1 5740-CB1 2.4 08/12/2005 20.55.23 OPT/II 8.5 DCX.SR.FW.....
TEST003 54,944 TEST003 23,388 7,446 15,942 VSR1 5740-CB1 2.4 10/06/2010 19.30.52 NONE