After migrating to CA Intertest for CICS r 10 the client has messages that PPT RDO entries IN67AIDB and IN67LECS are missing.

book

Article ID: 6755

calendar_today

Updated On:

Products

CA InterTest - CICS CA InterTest - Batch CA InterTest VSE - CICS

Issue/Introduction

The client just upgraded and stared CA Intertest for CICS r 10 in CTS 4.2. When the client selects option 1 of the VRPT verification report they see message that PPT RDO table entries are missing for programs IN67AIDB and IN67LECS.

VRPT shows the following messages next to the missing load modules.

IN67AIDB  Program not in PPT

IN67LECS  Program not in PPT 

 

Cause

The client was not using the CA Intertest for CICS r 10 CTS 4.2 CSD RDO entries. The client was using the CA Intertest for CICS r 9.1 CTS 4.2 RDO entries and these PPT entries did not exist in the previous release.

Environment

Z/OS CICS

Resolution

The client will migrate the CA Intertest for CICS r 10 CTS 4.2 CSD RDO entries to the DFHCSD file and start CICS pointing to the correct entries.  The CA Intertest for CICS r 10 CTS 4.2 CSD RDO entries are in  PDS HLQ.CAVHJCL(CSDINT67).