SMF records needed to populate some fields on UFILESYS after upgrade
search cancel

SMF records needed to populate some fields on UFILESYS after upgrade

book

Article ID: 66995

calendar_today

Updated On:

Products

SYSVIEW Performance Management

Issue/Introduction

Under a z/OS GA system with the DEVSUP option NON_VSAM_XTIOT=YES, the command UFILESYS does not display any I/O counts,

i.e. columns from RdCnt to WrByt are empty.


Under a z/OS GA-1 system with the DEVSUP option NON_VSAM_XTIOT=NO, it's working fine.


Resolution

This is not related to the z/OS release upgrade, as thought. 

SMF type 92 records will need to be generated in order to populate the following fields on the UFILESYS display in SYSVIEW:

rdcnt, wrcnt, rdiob, wriob, driob, rdbyt, wrbyt, moves. 

On this z/OS GA system, there are no SMF type 92 records as opposed to the z/OS GA-1 system, where those records were collected.