Message CAIN4569 UBP4567 facility not generated when setting Intertest for CICS breakpoint?
search cancel

Message CAIN4569 UBP4567 facility not generated when setting Intertest for CICS breakpoint?

book

Article ID: 66127

calendar_today

Updated On:

Products

InterTest - CICS

Issue/Introduction

When attempting to set an unconditional breakpoint in a program using Intertest for CICS, the programmer receives the following messages:

CAIN4569 UBP4567 facility not generated.
CAIN4511 Please consult your System Programmer.
CAIN4502 This request disregarded.
CAIN4532 Depress CLEAR for return.

 

Environment

Z/OS

CICS

Resolution

The CAIN4569 message is generated when the InterTest for CICS IN25OPTS option parameter BREAK=NO is set. 

BREAK=YES/NO
Indicates whether InterTest for CICS is allowed to execute breakpoints.

YES
Allows InterTest for CICS to execute breakpoints; that is, to stop execution of the application program at certain points. Select this option if you intend to use Intertest for CICS as an interactive debugging tool.

NO Intertest for CICS to execute breakpoints. This option might be desirable in a separate version of Intertest for CICS used solely for monitoring production applications. Intertest for CICS generated with BREAK=NO monitors with less overhead, which is important in production.

Instead of causing automatic breakpoints, Intertest for CICS abnormally terminates transactions with a transaction dump when it detects a standards violation. The abend/dump code is INTE. The dump contains all of the usual diagnostic information.

CAIN3501 TASK=00052 ABENDED BY CA INTERTEST, ABEND CODE=INTE, ERROR CODE=37
CAIN3502 PGM=COBDEMO OFFSET=000012B8 TRANS=DEMC, TERM=U012.