Issue/Introduction
During initialization of Sysview Performance Management Option for Db2 for z/OS the Data Collector (DC) started task fails with a Return Code (RC) of 32 without any other message.
Environment
Release: 20.0 Component: Sysview Performance Management Option for Db2 for z/OS
Resolution
RC=0032 indicates an error with input parameters for the Data Collector started task. In the present case it was a typo of DBLOA instead of DBLOC.