One of our CA XCOM Data Transport for z/OS r12 batch jobs got a S092A abend:
XCOMM0027I XCOMSTIM ESTAE ROUTINE HAS BEEN ESTABLISHED
XCOMM0053E ABEND S92A IN MODULE(XCOMJOB ), OFFSET(+0102CEA2)
XCOMM0054I PSW at entry to ABEND: 070C1000 81033EA4
XCOMM0054I Data near PSW: 840018F5 0A0DA768 00001816
XCOMM0054I Abending Instr ---------*
XCOMM0054I Registers at entry to ABEND:
XCOMM0054I 0-3: 000002C0 8492A000 0000092A 0000092A
XCOMM0054I 4-7: 0000092A 00000018 008FFDA0 00F79280
XCOMM0054I 8-B: 00F79280 01035320 7FFF8F00 2E4A4948
XCOMM0054I C-F: 7FFF8180 7FFF8354 81033E12 00000018
IBM z/OS
CA XCOM Data Transport for z/OS
xcmvs
Here is the explanation of this abend:
92A
Explanation: During processing of an ATTACH macro, an environmental error
occurred that was not caused by the current task. Register 15 contains a
hexadecimal reason code that explains the error:
Code
Explanation (from R15)
18
ATTACH is unable to obtain a linkage stack for the task.
Looking at this explanation for this abend, it says "an environmental error occurred that was not caused by the current task". This is not an XCOM problem. Adjust the storage for this region.