OPS/MVS OPSUSS Abend 0C6 in OPSUSSSV
search cancel

OPS/MVS OPSUSS Abend 0C6 in OPSUSSSV

book

Article ID: 6101

calendar_today

Updated On:

Products

OPS/MVS Event Management & Automation

Issue/Introduction

I am receiving a 0c6 abend when starting OPSUSS task on LPAR with new OPSMVS implementation. The error information is below:

4.25.47 STC13842 @OPS3000S ESTAE LEVEL 1 PROGRAM CHECK CODE=0C6 TIME=14:25:47 SEQ=0 CPU=00 ASID=0093 (0093 0093)
14.25.47 STC13842  +OPS3006I PSW AT TIME OF ERROR 078D1000 AF53D0EB ILC 2 INTC 06 RSCD 00000006                 
14.25.47 STC13842  +OPS3007I CURRENT ROUTINE NAME=OPUSSSV ADDRESS=2D4010A8 OFFSET=UNKNOWN                       
14.25.47 STC13842  +OPS3008I GPR  0-3  00000064 2D4BAA84 2D4BA030 2D4CB930                                      
14.25.47 STC13842  +OPS3008I GPR  4-7  008ECD48 00000000 008D3FC8 00FC8B80                                      
14.25.47 STC13842  +OPS3008I GPR  8-11 2D4BAA84 2D40182E 2D407000 2D4B9E60                                      
14.25.47 STC13842  +OPS3008I GPR 12-15 07CD4000 2D4B9E90 AD401872 AF53D0E9                                      
14.25.47 STC13842  +OPS3008I AR  0-3  00000000 00000000 00000000 00000000                                       
14.25.47 STC13842  +OPS3008I AR  4-7  00000000 00000000 00000000 00000000                                       
14.25.47 STC13842  +OPS3008I AR  8-11 00000000 00000000 00000000 00000000                                       
14.25.47 STC13842  +OPS3008I AR 12-15 00000000 00000000 00000000 00000000                                       
14.25.47 STC13842  +OPS3009I ABENDING LOCATION  OPUSSSV+UNKNOWN                                                 
14.25.47 STC13842  +OPS3009I UNKNOWN  CALLED BY OPUSSSV+UNKNOWN                                                 
14.25.47 STC13842  +OPS3009I OPUSSSV  CALLED BY OPSAMD+X'9F2'                        
14.25.47 STC13842  +OPS3009I OPUSSSV  CALLED BY SYSTEM+UNKNOWN                       
14.25.47 STC13842  IEA995I SYMPTOM DUMP OUTPUT  837                                  
   837             SYSTEM COMPLETION CODE=0C6  REASON CODE=00000006                  
   837              TIME=14.25.47  SEQ=06259  CPU=0000  ASID=0093                    
   837              PSW AT TIME OF ERROR  078D1000   AF53D0EB  ILC 2  INTC 06        
   837                NO ACTIVE MODULE FOUND                                         
   837                NAME=UNKNOWN                                                   
   837                DATA AT PSW IS UNAVAILABLE AT THIS TIME                        
   837                GR 0: 00000000_00000064   1: 00000000_2D4BAA84                 
   837                   2: 0000014E_2D4BA030   3: 00000000_2D4CB930                 
   837                   4: 00000000_008ECD48   5: 00000000_00000000                 
   837                   6: 00000000_008D3FC8   7: 00000000_00FC8B80                 
   837                   8: 00000000_2D4BAA84   9: 00000000_2D40182E                 
   837                   A: 00000000_2D407000   B: 00000000_2D4B9E60                 
   837                   C: 00000000_07CD4000   D: 00000000_2D4B9E90                 
   837                   E: 00000000_AD401872   F: 00000000_AF53D0E9                 
   837              END OF SYMPTOM DUMP

Environment

OPS/MVS

Cause

An old/prior version of OPSAEX  in LPA library can cause a wide variety of errors in OPS/MVS.  If you have experienced any other 'odd' abends in OPS/MVS this is probably the culprit.

Resolution

Remove all references to the old OPSAEX from LPA as soon as possible.

Additional Information