When trying to activate one of the JTS tables and it doesn't load, a TRAC733E message is issued in the Jobtrac started task log. To address this increase the size of the table identified in the TRAC733E error message.
This message means the allocated storage for the table is not large enough and you will need to increase the size.
In the JOBTRA00 member of the PPOPTION dataset the values are specified. Below show the default value. We recommend you double the current size. The maximum value is 25000.
TSCMDSPA=xxxxx /* CMD TABLE (DEFAULT=250) */
TSDSNSPA=xxxxx /* DSN TABLE (DEFAULT=100) */
TSMSGSPA=xxxxx /* MSG TABLE (DEFAULT=250) */
TSPGFSPA=xxxxx /* PGF TABLE (DEFAULT=300) */
When increasing the above parms, you will then need to recycle CA Jobtrac with a BACK.
As always, please contact Broadcom support for Jobtrac Job Management if you have further questions.