What action is needed when message TRAC733E occurs while trying to load one of the product's JTS tables?
search cancel

What action is needed when message TRAC733E occurs while trying to load one of the product's JTS tables?

book

Article ID: 60089

calendar_today

Updated On:

Products

Jobtrac

Issue/Introduction

When trying to activate one of the JTS tables and it doesn't load,  a TRAC733E message is issued in the  Jobtrac started task log.   To address this increase the size of the  table identified in the TRAC733E error message.

Environment

Release:
Component: JOBTRC

Resolution

This message means the allocated storage for the table is not large enough and you will need to increase the size.

In the JOBTRA00 member of the PPOPTION dataset the values are specified. Below show the default value. We recommend you double the current size. The maximum value is 25000. 

TSCMDSPA=xxxxx    /* CMD TABLE (DEFAULT=250) */      
TSDSNSPA=xxxxx /* DSN TABLE (DEFAULT=100) */
TSMSGSPA=xxxxx /* MSG TABLE (DEFAULT=250) */
TSPGFSPA=xxxxx /* PGF TABLE (DEFAULT=300) */

When increasing the above parms, you will then need to recycle CA Jobtrac  with a BACK.