When trying to apply maintenance to ACF2 for DB2, the following SMP/E errors occur:
GIM38201E ** THERE IS A MODID ERROR FOR DATA ENTRY CADB2C10 IN SYSMOD RO25436.
GIM31901I SYSMOD RO25436 DOES NOT SPECIFY RO25433 ON THE PRE OR SUP OPERAND.
THAT IS CURRENTLY INSTALLED.
GIM22601I APPLY PROCESSING FAILED FOR SYSMOD RO25436.
GIM38201E ** THERE IS A MODID ERROR FOR DATA ENTRY CADB2C11 IN SYSMOD RO65361.
GIM31903I SYSMOD RO65361 DOES NOT SPECIFY RO65360 ON THE PRE OR SUP OPERAND.
THAT IS BEING INSTALLED.
GIM22601I APPLY PROCESSING FAILED FOR SYSMOD RO65361.
The following errors occur when trying to apply maintenance to Top Secret for DB2:GIM38201E ** THERE IS A MODID ERROR FOR DATA ENTRY CADB2C10 IN SYSMOD RO25433.
GIM31901I SYSMOD RO25433 DOES NOT SPECIFY RO25436 ON THE PRE OR SUP OPERAND.
THAT IS CURRENTLY INSTALLED.
GIM22601I APPLY PROCESSING FAILED FOR SYSMOD RO25433.
GIM38201E ** THERE IS A MODID ERROR FOR DATA ENTRY CADB2C11 IN SYSMOD RO65360.
GIM31903I SYSMOD RO65360 DOES NOT SPECIFY RO65361 ON THE PRE OR SUP OPERAND.
THAT IS BEING INSTALLED.
GIM22601I APPLY PROCESSING FAILED FOR SYSMOD RO65360.
Release: ACF2 - Option for DB2 v1.3
Release: Top Secret - Option for DB2 v1.3
The problem is that the 2 fixes are for the same FMID CBAV130, but only one should be applied.
RO25433 is for ACF2/DB2.
RO25436 is for Top Secret/DB2 (TSS/DB2).
RO65360 is for ACF2/DB2.
RO65361 is for Top Secret/DB2 (TSS/DB2).
CBAV130 is a FMID shared by ACF2/DB2 and TSS/DB2, and it is actually the same code. The only difference is that the dataset CACPLINK is used by ACF2/DB2, while CADBLINK is used by Top Secret/DB2.
The PTFs applied need to be removed (REJECT). Then only the PTFs corresponding to the ESM running in the system should be applied.