Encountering the following messages when starting a Sysview for Db2 for z/OS (IDB2) Data Collector:
DBG39049I 22:30:54 INITIALIZING CA SYSVIEW FOR DB2 nn.0
DBG99001E xxxx 22:30:54 ERROR IN COMMAND STREAM, PROCESSING ENDED OEVN003I OPSEVENT State: DOWN
DBG39039I xxxx 22:30:54 TERMINATION COMPLETE FOR DATA COLLECTOR FOR DB2 SUBSYS
The problem was caused by the use of non numerical value for the suffix.
The problem was caused by the use of non numerical value for the suffix.
PARMLIB/XMAN/XNET Parameters
The following parameters are used to locate connection plan names and XNET and XManager address spaces:
ENV=nn
Specifies the environmental suffix value that determines which parmlib members to use. The parmlib members control which plan names and Xmanager task to use. If SUFFIX is also coded, the ENV parameter is used instead.
If you specify non numerical value, include the value in single quotation marks. For example, 'XX'.
SUFFIX=nn
Specifies the suffix value to use when reading parmlib members. The parmlib members control which plan names and Xmanager task to use. If ENV is also coded, the ENV parameter is used instead.
Default: 00
If you specify nonnumerical value, include the value in single quotation marks. For example, 'XX'.