Database Analyzer for Db2 job abends with S92A
search cancel

Database Analyzer for Db2 job abends with S92A

book

Article ID: 57637

calendar_today

Updated On:

Products

Database Analyzer for DB2 for z/OS

Issue/Introduction

Database Analyzer for Db2 for z/OS (PDA) job is receiving an abend code of S92A with the following message: 

SYSTEM COMPLETION CODE=92A REASON CODE=00000018 
TIME=07.51.15 SEQ=42236 CPU=0000 ASID=0746 
PSW AT TIME OF ERROR 070C1000 810E417C ILC 2 INTC 0D 
NO ACTIVE MODULE FOUND 
NAME=UNKNOWN 
DATA AT PSW 010E4176 - 840018F5 0A0DA768 00001816 
AR/GR 0: 00000000/000002C0 1: 00000000/8492A000 
2: 00000000/0000092A 3: 00000C05/0000092A 
4: 00000000/0000092A 5: 00000000/00000018 
6: 00000000/008FFAB8 7: 00000000/00F3A400
8: 00000000/00F3A400 9: 00000000/010E55F8 
A: 00000000/7FFF8F00 B: 00000000/7F338938
C: 00000000/7FFF8440 D: 00000000/7FFF8614
E: 00000000/810E40EA F: 00000000/00000018 
END OF SYMPTOM DUMP 
IEF450I NNPT16V1 STEP1 - ABEND=S92A U0000 REASON=00000018 

Cause

The job did change. The amount of database objects has increased.

Resolution

If possible obtain the region needed to run the job.  When running the job with 0M for region, make sure the site policies allows it or there
is no exit in place  that will prevent the job from getting all the region that is needed to run to completion. 

If option 1 is not possible, then the job needs to be broken up to a more manageable size.