Many probes are down on the primary with java errors in the logs.
search cancel

Many probes are down on the primary with java errors in the logs.

book

Article ID: 5741

calendar_today

Updated On:

Products

DX Unified Infrastructure Management (Nimsoft / UIM)

Issue/Introduction

All of the probes that depended on the java.exe were in a down status with errors in the logs that the probes could not find the path to java.exe.

 

 

Environment

Release: Any UIM 

java_jre 1.6 - 1.7

Cause

The root cause of the issue resulted from the probes losing their path to the nimsoft/jre/jre7/bin/java.exe folder structure.

Resolution

By deploying the appropriate java_jre (e.g. java_jre-1.72) from the Archive to the primary server robot, we were able to help the probes find the path to the java.exe once again.  The primary robot also has to be restarted for the changes to take effect.  Once these steps were taken, all of the probes are now functioning as normal and without issue.