When logging into the View 3270 interface, I receive the message VKG0170D No Object Records Returned. What is wrong?
Vantage
There are 3 possible causes for this error:
1. After upgrading you have updated your PROFPFX data set, but your own profile has not been updated.
You need to delete your profile data set and log back on to Vantage. A new profile data set will get allocated with the current settings.
2. You are not pointing to the correct PROFPFX data set. This data set was allocated during the install of the product with a name of installation_prefix.PROFILE. To correct the problem, set the PROFPFX parameter to the value of the installation_prefix that was used during the installation.
3. You are logging in for the first time and you do not have the authority to allocate the HLQ that is specified in the PROFPFX parameter, so you cannot allocate a profile data set. You must either have your Security Administrator grant you that access or you will have to access all the objects through the '__Object' header on the top left of the View3270 screen. All objects will still be available, but you will not be able to create your own welcome screen.