Issue/Introduction

Attempting to update a member in a Librarian Master file and getting the following message:

                           OUTPUT MODULE TOO LARGE TO PROCESS

 

Environment

 Release:   4.4

 

Resolution

This message indicates the member has hit the 255 physical block limit.  There are some immediate and long-term solutions to address this concern:

     1.  Delete one or more of the oldest archive levels.
          (This is a temporary solution; the problem can reoccur again when additional updates are made.)

     2.  Decrease the number of Archive levels specified for the Master file
          (This is a more permanent solution.)
 
 
     3.  Increase the blocksize of the Master file.
          (This is a more permanent solution.)

 
     4.  Convert the master file to Wide Record Master File format.
          (This is a permanent solution as Wide Record Master File members do not have a 255 physical block limit.)

 

Additional Information

Refer to KB article:  51852 on how to delete archive levels from a Librarian member.

Refer to KB article:  56714 on how to change the ARC level in an existing Librarian Master file.