XCOM for z/OS will write NetView Alerts when the ALERTS parameter is set in the config member for conditions that meet a specified event category and severity level. This parameter may also be set in a destination member.
XCOM™ Data Transport® for z/OS
Multiple categories of ALERTS may be specified with the ALERTS parameter. You must have a NetView receiver available on the system where the XCOM server is running.
Event categories are CONVersation, SESSion, FILE, SECurity, GEN
Severity levels are: Information, Warning, Error, Action, NONE
Refer to the Config Member Alert Parameters for details on setting ALERTS in config members.. Refer to Destination Member Alert Parameters for setting ALERTS in the destination members.
Individual XCOM error messages are marked internally for:
Everytime XCOM writes a message to the XCOMLOG or MVS console, it checks the message to determine if it is eligible for ALERTS and if it matches an ALERTS category set in the DEFAULT table or destination member.
Here are some examples: