1R30I - Invalid CCW during APAR apply (using MSHP)
search cancel

1R30I - Invalid CCW during APAR apply (using MSHP)

book

Article ID: 55294

calendar_today

Updated On:

Products

Dynam for VSE Dynam VSE Option

Issue/Introduction

Trying to apply APAR using MSHP under Dynam/D control can result in:

BG 0000 CADD002I ALLOCATED FILE=FILE02 SYS002=222 TMPDX2 X=0/8/15000.
BG 0000 CADD028I ACCESSED FILE=FILE02 SYS002=222 TMPDX2 X=0/8/15000.
BG 0000 M275I CATALOG OF MEMBERS IN PROGRESS
BG 0001 1R30I INVALID CCW - CCB ADDR=X'7210F8' PTFZVSE 00659, X'00C' RC=0002
PARTITION BG
BG 0001 1R30I CCB=0000A000 0C200000 00721168 00721170, ADDR=007210F8, BG
BG 0001 1R30I CCW=01000000 20000142, ADDR=00721168, BG
BG 0000 0P73I I/O ERROR

Resolution

Using Work files under Dynam/D control ...

You need to check the following Options:

DYNAM/D=YES
DISK=3390,FBA
.
WKASN=ON must be defined if more than 1 DASD model is specified in DISK=