Missing $A00311 $A10311 I600311 after receiving PTFs and trying to apply the PTFs
search cancel

Missing $A00311 $A10311 I600311 after receiving PTFs and trying to apply the PTFs

book

Article ID: 55099

calendar_today

Updated On:

Products

Easytrieve Report Generator

Issue/Introduction

After receiving maintenance and trying to do an APPLY CHECK, the listing shows messages stating that these are missing for different 6.4 PTFs:

$A00311    $A10311      I600311

How may this be resolved?

 

 

Environment

Easytrieve Plus Report Generator, release 6.4

Resolution

These FMIDS do not need to be downloaded.

The PTFs getting these messages may be installed "as is" to an Easytrieve Plus release 6.4 0311 (SP01) genlevel upgrade.

If the SP01 gen level was installed as a new installation and not as an upgrade, then the SMP control parameter for each of the PTFs must be modified before it can be applied.

That modification is to remove the "PRE" parameter before RECEIVING and APPLYING the apar(s).