Running a LIBINDEX getting DMSITP143T Addressing exception occurred at 80F13534 in system routine NUCEXT; Re-IPL CMS

 

Environment

Release:
Component: C21E

Resolution

The LIBRARIAN segment was being corrupt by CMS. User needs to redefine the segment and reloaded the segment. Steps to follow:

  1. Purge the segment and redefine and reload the segment.

  2. DEF STOR 16M
    SET MACHINE ESA
    I CMS

  3. Re-IPL'

  4. Run LIBGEN.

  5. After a successful run of LIBGEN, enter the Following:

    DEF STOR 12M
    SET MACHINE XA