Sysview for Db2 Data Collector startup fails with the error DBG72032E ERROR INVOKING IMOD $DBGL_ILOGMSG
search cancel

Sysview for Db2 Data Collector startup fails with the error DBG72032E ERROR INVOKING IMOD $DBGL_ILOGMSG

book

Article ID: 54913

calendar_today

Updated On:

Products

SYSVIEW Performance Management Option for DB2 for z/OS

Issue/Introduction

A Sysview for Db2 for z/OS (IDB2) Data Collector will not start due to error:

    IDB2 11.5.1 DATA COLLECTOR 
    DBG21002I ssid 13:19:56 HISTORY, INITIALIZATION COMPLETED 
    DBG72032E ssid 13:20:01 ERROR INVOKING IMOD $DBGL_ILOGMSG ON ISERV ISRV 
    (RC=0016-00000018) FOR THE FOLLOWING EXCEPTION: 
    DBG11016I ssid 13:20:01 GSS ERROR: GSS SSCVT not found

Resolution

Remove the '*' in the IDDCPRMS member for the parm CALL-GSS=YES and change the parm to state: CALL-GSS=NO.
The IDDCPRMS member is located in the IDB2 hlq.SOURCE library.