CAS9DB Utility RC=08. Job name ENFDBINT Fails no obvious reason.
book
Article ID: 54850
calendar_today
Updated On:
Products
CA 1 Flexible StorageCA 1 Tape Management - Copycat UtilityCA 1 Tape Management - Add-On OptionsCompress Data Compression for MVSCompress Data Compression for FujitsuDatacomDATACOM - ADCISCOMMON SERVICES FOR Z/OS90S SERVICESDATABASE MANAGEMENT SOLUTIONS FOR DB2 FOR Z/OSCOMMON PRODUCT SERVICES COMPONENTCommon ServicesCA ECOMETER SERVER COMPONENT FOCEasytrieve Report Generator for Common ServicesINFOCAI MAINTENANCEIPCUNICENTER JCLCHECK COMMON COMPONENTMainframe VM Product ManagerCHORUS SOFTWARE MANAGERCA ON DEMAND PORTALCA Service Desk Manager - Unified Self ServicePAM CLIENT FOR LINUX ON MAINFRAMEMAINFRAME CONNECTOR FOR LINUX ON MAINFRAMEGRAPHICAL MANAGEMENT INTERFACEWEB ADMINISTRATOR FOR TOP SECRETXpertware
Issue/Introduction
Description:
When running CAS9DB Utility it ends RC=08 without providing meaningful messages. Job ENFDBINT, commands INIT, INST, LIST.
Environment
Release: Component: ENF
Resolution
Solution:
The most common causes of this high return code are:
There are missing entries in your z/OS SYS1.PARMLIB member IKJTSO00. See PDC #'s QI64746 & QI69116 which document the need to have the following modules to IKJTSOXX AUTHCMD section-
CAS9UDTN & CAE$BQRY
The system AUTHCMD IKJTSOXX settings can be dynamically refreshed with the MVS SET command -
T IKJTSO=xx where XX = the suffix of your IKJTSO member.
One or more of your product DCMs (Data Collector Modules) cannot be found via STEPLIB nor LINKLIST.
One or more of your product DCMs (Data Collector Modules) that you are installing is not APF authorized.
You have a syntax error in your utility control statements.