Dynam for VSE Dynam VSE Option

Issue/Introduction

Description:

It may happen that you are running into CADC104E Catalog is full

Solution:

DYNCAT BACKUP NODEQ
DYNCAT RESTORE REORG

CHECK THE VALUE OF "HIGH WATER MARK:" , THIS IS A VALUE IN PERCENT
AND CAN BE FOUND IN THE PRINTLOG OF RESTORE REORG OR IN CUI IN THE
PANEL CAYD-1500 SYSTEM STATUS INFORMATION
IN CASE THIS VALUE IS GREATER THAN 80 % YOU SHOULD PLAN TO INCREASE
THE DYNAM CATALOG NEXT TIME, IF GREATER THAN 90 % YOU SHOULD INCREASE
AS SOON AS POSSIBLE AS YOU WILL RUN INTO THIS PROBLEM VERY SOON AGAIN.

PLEASE BE AWARE , WHEN INCREASING THE CATLOG THIS WOULD RESULT INTO A CHANGE
TO THE EXTENT INFORMATION TO CAICATL IN THE STDLABEL , ALSO AN IPL
MUST BE PERFORMED.

Environment

Release:
Component: DYNVS